| Functions and Features | | | | | | | | |
| | | | | | | | | | | | |
| 1.Solar charger for lead acid batteries | | Input power: 260W | Bitmap |
| 2.High efficient, energy-saving, safety | | L×W×H:163×100×47mm |
| 3.Temp compensation | | | | Color:Black |
| 4.Electric energy instruction | | | | |
| 5.Protections: | | | | | |
| | ·battery reverse polarity | | | Application: |
| | ·solar panel reverse polarity | | Solar power system |
| | ·load over-current | | | | |
| | ·short-circuit | | | | | |
| | ·battery open-circuit polarity | | | | | | | |
| | | | | | | | | | | | |
| INPUT |
| 1 | Input voltage range | VDC | 12~25 |
| 2 | Over-Charge Protection | VDC | 14.4±0.3 |
| 3 | Over-Charge Resume | VDC | 13.3±0.3 |
| OUTOUT |
| 4 | Normal output voltage | VDC | 12 |
| 5 | Max output current | A | 20 |
| 6 | Over-Discharge Cut-off | VDC | 11.1±0.3 |
| 7 | Over-Discharge Resume | VDC | 12.4±0.3 |
| 8 | Over-Loaded Cut-off | VDC | 16.5 |
| 9 | Over-Loaded Resume | VDC | 15 |
| 10 | Voltage Drop | VDC | 0.4 | Between input and batteries |
| 11 | Voltage Drop | VDC | 0.3 | Between batteries and load |
| 12 | No Load Current Draw | mA | <10 |
| 13 | LED indication | - | flashing: energy; green: load |
| 14 | Temp. compensated factor | | From-4mV/℃ to -6mV/℃ per unit (Optional) |
| ENVIRONMENT |
| 15 | Operating temperature | ℃ | 10~+40 | Max load & normal conditions |
| 16 | Operating humidity | % | <90(RH) |
| 17 | Storage temperature | ℃ | 20~+70 |
| 18 | Cooling | - | Normal conditions |
| 19 | Vibration | - | 5mm/50Hz/600s | Non-operating condition |
| MECHANICPI |
| 20 | Plastic casing color | - | Pantone: 419C, black |
| 21 | Weight | g | 390 |
| 22 | Size | mm | 163×100×47 |
| SAFETY |
| 23 | Temperature rise | ℃ | <40 on plastic casing | | | Max load |
| 24 | MTBF | hrs | >10000 |
| 25 | ESD | KV | 8 |